R911310381 / 02 | Rexroth IndraControl VCP 20 Electric Drives and Controls | Bosch Rexroth AG 7-15
Interfaces
7.4 Shielding D-SUB Connectors
You must shield D-SUB connectors as follows:
Fig. 7-27: Shielding D-SUB connectors
1 D-SUB connector
2 Shield
3 Cable clip
4 Cable
The shield must be folded back into a flat position over the cable
sheath.
When fastening the cable with the cable clip, as much of the shielding
as possible must be in contact with the housing and sufficient strain
relieve must be ensured.
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com