7 Technical data
Processor IndraControl XM4: Intel® Core™ i Dual Core 6th generation
RAM 4 GByte DRAM DDR4
Connection for extension mod-
ules
Via the bus base XA-BS03
Extension bus
Number of possible modules
3
Connection for S20 I/O Via the bus base XA-BS03
S20 bus parameters
Transmission rate
Number of connectable mod-
ules
Max. current for the S20 bus
(U
Bus
)
100 MBit/s
Max. 63 (per station)
2 A
Communication interfaces RJ-45 connections:
● 1 × Ethernet connection (10 MB, 100 MB, 1 GB)
● 2 × Sercos III master-slave interfaces
● 2 × Ethernet field bus master-slave interfaces
USB ports:
● 1 × USB host, maximum cable length 3 m (for the functionality,
refer to the system description of the respective system).
The USB memory sticks with the file systems FAT16 and FAT32
are supported.
Plugging in and removing the USB memory medium at
runtime is generally possible. However, it can cause a
temporarily increased runtime behavior and motion
cycle time exceedances or PLC and hardware watch-
dogs in case of a high control load. Thus, plug in or re-
move a USB memory medium only in an uncritical ma-
chine state (e.g. home position)!
● 1 × USB device, maximum cable length 3 m (for the functionality,
refer to the system description of the respective system).
IndraControl XM42 Controls 9/65
Technical data
R911345566_Edition 03 Bosch Rexroth AG