Electrical data
Single-ended
Data Symbol Unit min. typ. max.
Input voltage
U
ext
V 5 30
Current consumption at U
ext
I
ext
mA 25
25 + 3×I
out
Output voltage "high"
U
Out_High
V
U
ext
- 2V
U
ext
Output voltage "low"
U
Out_Low
V 0 1.5
Output current
I
Out
mA - 40
Overload protection - - Present
Short circuit protection - - Present
Tab. 8-9: Single-ended
RS422
Data Symbol Unit min. typ. max.
Output voltage "high"
U
Out_High
V 2.5 5
Output voltage "low"
U
Out_Low
V 0 0.5
Output current
I
Out
mA - 20
Overload protection - - Present
Short circuit protection - - Present
Tab. 8-10: Outputs, RS422
Data Symbol Unit min. typ. max.
Input voltage "high"
U
In_High
V 2.5 5
Input voltage "low"
U
In_Low
V 0 0.5
Input resistance (difference)
R
In_D
ohm 110 130
Input resistance
R
In
kOhm 150
Overload protection - - Present
Short circuit protection - - Present
Tab. 8-11: Inputs, RS422