Digital Outputs (Safety Technology L Options)
The
digital outputs are compatible with digital inputs of types 1, 2 and 3
(IEC 61131).
Fig. 8-31: Symbol
Data Unit Min. Max.
Supply voltage (U
ext
) V 19,2 30
Current consumption (I
ext
) mA 700
Output voltage ON V 18,2 30
Output voltage OFF V 5
Output current ON mA 350
Allowed energy content of con‐
nected inductive loads, e.g. re‐
lay coils; only allowed as single
pulse
mJ 400
Short circuit protection Available
Overload protection Available
Tab. 8-32: Digital Outputs (Safety Technology L Options)
Bosch Rexroth AG DOK-INDRV*-CXX02******-PR03-EN-P120/143
IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02
Technical data - functions
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com