Digital Outputs (Safety Technology S Options)
The
digital outputs are compatible with digital inputs of types 1, 2 and 3
(IEC 61131).
Data Unit Min. Max.
Output voltage ON V U
ext
- 1 U
ext
Output voltage OFF V 2
Allowed output current per out‐
put
mA 350
Allowed energy content of con‐
nected inductive loads, e.g. re‐
lay coils; only allowed as single
pulse
mJ
400
1) 2)
Short circuit protection Available
Overload protection Available
Block diagram output:
Error Detection The following errors are detected:
Wiring error with short circuit to high
Wiring error with short circuit to low
Wiring error with short circuit between the
two channels
Internal errors
In the case of an error, the control panel shows
the corresponding error message: F83xx
1) With a maximum switching frequency of 1 Hz
2) In the case of inductive loads with currents > 200 mA or in the
case of inductive loads with a greater energy content, an exter‐
nal free-wheeling arm must be installed. The effective terminal
voltage must be < 25 V.
Tab. 8-33: Digital Outputs
DOK-INDRV*-CXX02******-PR03-EN-P Bosch Rexroth AG 121/143
IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02
Technical data - functions