ESD Protection
Risk of damage to the control section and in‐
terference
with its operational safety caused
by electrostatic charges!
Exposed conductive parts coming into contact with the control section must
be previously discharged by means of grounding.
Such exposed conductive parts include:
● The
human body (ground connection by touching a conductive, groun‐
ded object)
● Parts and tools (place them on a conductive support)
Control sections may only be stored or dispatched in conductive packaging.
Limited Number of Plug-In Actions
Risk of damage to the control section or pow‐
er section by mounting and dismounting the
control section too often!
For a drive controller, the control section must not be mounted and dismoun‐
ted more than a maximum of 20 times.