6.8 X32 (single-axis), analog input
View Connec‐
tion
Signal name Function
1 GND_100 Connection for inner cable shield
2 IA_1- Analog input
3 IA_1+
Spring terminal (con‐
nector)
Unit min. max.
Connection cable
Stranded wire
mm
2
0.2 1.5
AWG 24 16
Stripped length mm - 10
Shielding - - Only use shielded cables for cable lengths > 30 m.
Tab. 6-10: Function, pin assignment, properties
Shield connection
chapter 9.3 "Analog inputs/outputs: Shield connection" on page 130
Technical data
chapter 8.8 "Analog Voltage Input" on page 123
DOK-INDRV*-CXX02******-PR03-EN-P Bosch Rexroth AG 55/143
IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02
On-board connection points