12.10.1 Creating the control
To continue with the commissioning of the control, proceed as follows:
1. Start IndraWorks Engineering
Start IndraWorks Engineering on your project planning PC.
2. Create a project
Start IndraWorks Engineering and select "Empty project" as template.
Specify the project name and the required compatibility mode.
3. Selecting the control
Device-specific targets are selected via the device library. Select the device
"IndraMotion MLC VPx" in the device library and drag it with the left mouse
button pressed to the project node (here: Project 7) in the Project Explorer
and drop it on the left.
Fig. 12-16: Selecting the control in the IndraWorks device library
The commissioning wizard is automatically started for the IndraMotion
MLC controls.
IndraControl VPB 40.4
Bosch Rexroth AG
Device description
DOK-MLC***-INDRACTRLV4-IT02-EN-P