10-38 Interface ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Soft Fault:
"66Feed Angle Lost During Feed! "
"6AInvalid Mode Selection! "
Hard Fault:
"77Parameter Invalid! Select P-mode! "
"81Parameters Lost! Clear to Cont "
"86Parameters Lost! Select P-mode! "
Drive Error:
"00System is Ready "
"3DA: Stop/Wait for start "
"3ES: Stop active "
"3FM: Stop active "
"44Drive is not enabled! "
"7DMotor Overtemp Warning "
"7EAmp Overtemp Warning "
"82Axis 1 Drive Runaway! "
"88EMERGENCY STOP! "
"8BMotor Has Overheated! "
"8CDrive Stalled! "
"93Drive Watch Dog Error "
"96Drive Error, See H1 Display! "
Status 48
Actual Velocity in 1/min.
The status query:
?sX__48_CR LF
produces the message:
Xs48_g_vmmmm.mm_0_0000.00_$hh CR LF
Meaning of the characters used:
v = Operational sign
m = Velocity of Axis 1 in Revolutions/Min.
g = 0 = Axis deactivated
1 = Axis activated