Bosch Rexroth AG BT 6.00 1070080078 / 03
Assembly and Connection
3.1.2 Connection
For operation, the BT 6.00 needs the power supply to X1 as well as the
communication port X2 (RS 232 C, connected to X1 of the weld timer).
Location of the individual ports:
X2 X3 X1
Nameplate
PE
X1: Power supply input
X2: Communication with the weld timer (RS 232 C).
Used when the bootstrap mode for communication with a
PC is active (BT 6 firmware download).
X3: not used
PE: Threaded bolt for connecting the PE conductor
S1: Recessed button for activating the bootstrap mode.
S1
The control terminal may be connected and disconnected while the timer
is running.
Communication with the timer is automatically established when X2 has
been linked, if the BT 6.00 power supply (X1) had previously been inter-
rupted.
If the BT 6.00 power supply had not been previously interrupted, the
BT 6.00 signals that communication with the weld timer is not possible.
In this case, simply press the
key on the BT 6.00 in order to establish
communication.
. For more information on operation, refer to section 4.