Electric Drives
and Controls
35Bosch Rexroth AGBT 6.001070080078 / 03
Assembly and Connection
Power supply (X1)
Connection: Screw-type terminal connector, Phoenix
Combicon,
3-pole, max. 2.5
2
, MSTBV 2.5 / 3 GF.
Mating connector (female) is comprised in
the delivery.
Power supply: Safety extra-low voltage (SELV) in accor-
dance with DIN EN 61131.
19.2 ... 30.2 V
DC
; typ. 24 V
DC
Residual ripple max. 10 %.
Power input: < 0.3 A
Peak current: 0.5 A
Protection against polarity
reversal: Protective diode
Fusing: through semiconductor fuse, self-regen-
erating.
For more information, refer to page 53.
X1
+24 V
DC
0 V
DC
123
. The BT 6.00 can be supplied from, e.g., the X5 power output of the
weld timer.
. If shielded cables are used, connect the shield conductor to pin 1.
. The PE bolt is specifically provided for connecting the PE conduc-
tor. Operational safety is increased by using the PE connection.
Use a separate conductor with a minimum cross-section of
1.5 mm
2
for this connection.