Electric Drives
and Controls
4−3Bosch Rexroth AGBT 6.001070080078 / 03
Operation
4 Insertable stripes for labeling the function keys (cf. 2).
The delivery contains a labeled (”F1” to ”F6”) and an unlabeled insert-
able stripe.
5 Fault display key.
When a fault is present, the integrated LED flashes. By pressing a
key, you may branch to the fault display from any other display and
back to your starting point. Within the fault display, the BT 6 shows all
currently active faults automatically one by one. Refer to page 4−11.
To reset all active faults simultaneously: cf. item 7.
6 Key for direct selection of parameters.
The integrated LED is lit during parameter selection. By pressing the
key again, you may jump directly to the selected parameter.
For more information on ”Quick Mode”, refer to page 4−7 ff.
7 Delete/Quit button.
Deletes numerical values and resets active faults (timer is returned to
”Ready” status).
8 Return key.
Return to the main menu.
9 Plus and minus keys.
Decrement or increment the value in the display field, or change over
between options (e.g. ON / OFF, SINGLE / REPEAT / SEAM etc.).
10 Accept data key.
The value displayed is accepted. Control parameters are directly
transmitted to the timer.
11 Navigation keys.
or selects an input field or a menu item.
or steps sequentially through all display screens available
within a menu level.
jumps back by one menu level (to the display screen active before