44 Electric Drives
and Controls
Bosch Rexroth AG BT 6.00 1070080078 / 03
Operation
4.2 Main menu items and their functionality Overview
.
The scope of functions depends on the timer type connected! For
example, the number and representation of parameters or menu
items offered may be different, depending on the timer type used.
For this reason, the functionality of menu items or parameters will
not be dealt with in detail in this manual, which will rather be limited
to the handling of the BT 6.
. The following list shows the maximum scope of functions. It may
be limited for your timer type!
D Sequence. Options:
Display and change important parameters of the individual weld-
ing schedules (programs) (e.g. squeeze times, weld times includ-
ing heat values of all 3 current blocks, cool times, impulses and
upslope/downslope times in the 2
nd
current block, hold time, off
time, etc.)
F1 function key for direct selection
D Monitoring. Options:
Activate / deactivate current monitoring
Display and change tolerance limits
F2 function key for direct selection
D Last sequence. Options:
Information which schedule (program) ran last in the timer
For all programs: Display showing commanded/actual current and
mean heat value during last sequence
F3 function key for direct selection
D Stepper. Options:
Display wear, remaining parts and current status of all electrodes
(tip dress request, prewarning, end of stepper (electrode life))
Acknowledge replacement of electrodes (reset counter)
F4 function key for direct selection
D Correction in %. Options:
Display and change the correction values for heat and pressure,
for schedules and electrodes separately
F5 function key for direct selection
D Pressure. Options:
Display and change the basic pressure
Activate/deactivate the pressure profile, display and change indi-
vidual pressure profile values
D Diagnostics. Options:
Status display of all I/O signals