4−8 Electric Drives
and Controls
Bosch Rexroth AG BT 6.00 1070080078 / 03
Operation
4.4.1 List of parameter numbers for quick mode
.
The availability of individual parameter numbers depends on the
timer type connected!
Active range Description
(alternative description)
Parameter number
Weld program se-
quence
1.Squeeze time
extended squeeze time
1
Squeeze time 2
1.Weld time
Pre-heating weld time
3
1.Heat
Basic heating current
4
1.Cool time 5
Up-slope time
Time of current rise
6
Upslope heat 7
2.Weld time
Weld time
8
2.Heat
Basic heating current
9
2.Cool time 10
Down-slope time
Current decrease time
11
Downslope heat 12
3.Weld time
Post-heating weld time
13
3.Heat
Post-heating current
14
3.Cool time 15
Hold time 16
Off-time 17
Impulses 2.Weld time
Impulses
18
Sequence mode
Operating mode
19
Start inhibit (sequence) 20
Weld/no weld (sequence) 21
1.Halfwave a. Cool 22
Slope (on/off) 23
not used 24
Current monitoring Monitoring (Standard/Mix) 25
Standard: −
Current Monitor. Std 26
Reference curr. Std 27
Cond. Tol. Band Std 28
Repeat factor Std 29
Permitted upper tolerance plus tolerance 30
Permitted lower tolerance less tolerance 31
Mix: −