Electric Drives
and Controls
2−7Bosch Rexroth AGRhoMotion1070072365 / 04
System Overview
Technical data
Potential-free Ready contact 2-channel, triggered through:
D power supply monitoring
D Watchdog
D Temperature monitoring
Setting DIP-switch for component number
(LAN-Addressing), without function
at present, resp. for service purpo-
ses
Temperatur e operation ambient temperature 5 to 55 °C,
monitored
Temperature storage −25 to +70 °C
Protection type IP20 acc. to DIN VDE 0470
Resistance to jamming meets all set requirements acc. to
DIN EN 61131-2, DIN EN 50081-2
and DIN EN 50082-2
Air pressure Operation from sea level to 2000 m
acc. to DIN EN 61131-2
Protection class 1
Humidity class RH-2 acc. to DIN EN 61131-2
Degree of soiling acc. to DIN EN 61131-2
2.4 Operating conditions
The rho4.0 is designed for continuous operation (24 hours/day).
Unless stated otherwise in specific sections, these specifications apply:
Temperatures
Storage temperature:
D −25 °C to +70 °C
Ambient temperature
D +5 °C to +55 °C, monitored
Ambient temperatures apply to installation described in chapter 3.
Safety function
Temperature monitoring
The ambient air must not excess +55 °C. For the safety, a temperature
monitoring measures the temperature in the housing. At an ambient
temperature of +58 °C, the rho4.0 is brought into a safe state and shut
down.