Electric Drives
and Controls
5−11Bosch Rexroth AGRhoMotion1070072365 / 04
Interface Ports & Connectors
The metallic housing of the 100BaseT socket is set above the front shield
on the control housing resp. the shield. The cable shield is set above the
connector housing on the socket shield.
8
7
6
TXD
TXD−
5
Ethernet
4
RXD+
3
RXD−
2
1
max. 100 m
To the network
Ethernet RJ45
Free
Free
Free
Free
8
1
+
The line should have:
D a cross section of 0.08 mm@ to 0.34 mm@
D 100--impedance
D 12 to 45 twists per meter
Special cables for this use can be obtained under the following designa-
tion:
D STP cable, category 5 (STP = Shielded Twisted Pair)
D STP cable, category 6 (increasing category number means better ca-
ble properties)
. We recommend to use STP cables of category 5.
5.5.1 Ethernet (MAC)- and IP address
Ethernet Address
The rho4.0 has a fixed set ethernet address. This address is allocated
once in the world.
The ethernet address consists of 6 address bytes and has the following
structure:
Fixed part
Components specific
0xXX 0xXX 0xXX Xx yy zz
The address is entered in HEX.