3−14 Electric Drives
and Controls
Bosch Rexroth AG RhoMotion 1070072367 / 04
Structure of the rho4.0
3.3 Operation with I/O-Gateway
PLC controls of different busses can be connected to each other with the
B~I/O gateway and the modular bus connections B~I/O M-DP or B~I/O
M-IBS and B~I/O M-CAN.
A rho4.0 can also change 8 or 20 bytes inputs and outputs per B~IO M
bus connection via other field busses (Profibus, Interbus S, CANopen).
The selection 8 or 20 bytes can be set at the switch S1 of the I/O gateway.
. The B~IO M-CAN groups can be only used from Firmware Version
1.3 for I/O-Gateway
3.3.1 rho4.0 without PCL field bus card
The CAN bus of the rho4.0 is available for a B~IO M bus connection.
B~IO M-CAN
CAN-Bus 1 or
CAN-Bus 2 of the
rho4.0
I/O-Gateway B~IO M-
Bus connection
8 or 20 Byte
Field bus
Possible combinations:
CAN-Bus
of the rho4
B~IO M-
Bus connection
I/O-Gateway B~IO M-
Bus connection
Field bus
Can-Bus 1 or 2 B~IO M-CAN I/O-Gateway 8 Byte B~IO M-DP PROFIBUS-DP
Can-Bus 1 or 2 B~IO M-CAN I/O-Gateway 8 Byte B~IO M-IBS INTERBUS-S
Can-Bus 1 or 2 B~IO M-CAN I/O-Gateway 8 Byte B~IO M-CAN CANopen
Can-Bus 1 or 2 B~IO M-CAN I/O-Gateway 20 Byte B~IO M-DP PROFIBUS-DP
Can-Bus 1 or 2 B~IO M-CAN I/O-Gateway 20 Byte B~IO M-IBS INTERBUS-S
Can-Bus 1 or 2 B~IO M-CAN I/O-Gateway 20 Byte B~IO M-CAN CANopen