26/44 Bosch Rexroth AG SYHNC100-SEK...3X | RE 30162-B/04.11
Assembly
Wiring example for the SYHNC100-SEK...3X6.4.1
Use of pre-assembled breakout cables at the X8M encoder connector
interface and the analog I/O X2A
Breakout cable with HD-SUB, 15-poleFig. 4:
Shield clamp:1
the open end of the assembled breakout cable is connected with the terminal
block. Using a shield clamp which is adjusted to the shield strip, the pushed
back cable shield is pulled extensively to the potential of the control cabinet
rear wall, i.e the earth. The low-impedance connection of the conductively
coated DIN rail to the control cabinet rear wall is important.
SYHNC100-SEK...3X shield system2
The cable shields are connected with the VT-HNC100 housing via the HD-
SUB plug-in connector. The connection with the control cabinet rear wall
is established via the housing and the DIN rail. Metalized D-sub connector
housings are used. The cable shield must be pushed back and clamped under
the pull relief. See illustration below.
Breakout cable with 15-pole HD-SUB connector and open cable endFig. 5:
Max. length of the cable: 2 m