RE 30162-B/04.11 | SYHNC100-SEK...X Bosch Rexroth AG 27/44
Assembly
NOTE: On the side of the breakout cable, all wires must be connected to the
terminal strip. Otherwise there is a risk of short circuit!
The earthing of the control cabinet must be considered accordingly.
Wiring diagram for analog (X2A) or digital interface (X8M)
VT17220-1X/HNC100...3X & material number: R901189300
Wiring diagram for analog or digital interfaceFig. 6:
HD Sub connector high density 15-pole with solder bucket1
D-SUB housing, 9-pole, metal/UNC (mat. no. R900016918)2
Shrinkable tubing 30 mm3
Cable Unitronic LiYCY 8 x 2 x 0.14 mm4
2
, approx. 2.2 m
Shrinkable tubing 40 mm5
Wire end ferrules6
NOTE: Type and manufacturer of item 2 are binding (housing dimensions)
12
3
4
5
6
Provide litz wire
with pos. 6 wire
end ferrules
Shield put over outer
sheath
Shrink shield onto cable sheath
using a shrinkable tubing
Printed on the cable on both ends (smear-resistant), text height 3 mm