10-4
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual Device Programming
Devices > Keypads > L615
Beeper Options
MENU 6-1-5
1 Trouble Alert Beeps Y
2 Entry Warning Y
3 Exit Warning Y
4 Chime Tone Y
5 Display Temperature N
6 PIN Arming Not Allowed N
7 Installer PIN Not Allowed N
8 Reserved N
The above options can be congured independantly for
each keypad tted to the system.
1) Enter your Installer PIN + [MENU].
2) Enter [6] + [1] + [5] + [OK].
The keypad will display the current options which are
selected or enabled.
-bit-
1 2 3 4
3) Use the numeric keys [1] to [8] to turn on and o
the features as required. When the corresponding
number on the keypad is on then the option is
selected.
4) When all options are programmed, press [OK] to
save and exit, or press [MENU] to exit without
saving.
Trouble Alert Beeps
Setting this option will cause the keypad to sound a
trouble alert tone to notify the user that the panel has
a trouble condition that needs to be rectied. Press the
[OK] to acknowledge the trouble condition and stop the
alert tone. Press the down arrow for more information on
the trouble condition.
See MENU 7-7-1 — Area Options if you would like
to delay the audible trouble alert tone during the
night when the panel is used in residential
applications.
Entry Warning
Setting this option will cause the keypad to sound an
entry warning alert tone when the entry timer is running.
The tone will stop when a key is pressed or when the
entry time expires.
Exit Warning
Setting this option will cause the keypad to sound an exit
warning alert tone when the exit timer is running. The
tone will stop when the timer expires.
Chime Tone
Setting this option will cause the keypad to sound a
chime alert tone when a chime zone is faulted. Chime
zones are active when the area is disarmed and are
typically used to monitor the front door of a shop. The
chime alert tone will stop when the zone reseals.
Display Temperature
Setting this option congures the panel to always show
the current keypad temperature in the display. Each
keypad can be set to display its own temperature. It is
possible to trigger a temperature alarm based on the
keypad temperature. See MENU 7-7-3 — Keypad Hi/Lo
Temp for more information.
PIN Arming Not Allowed
Situations may arise where a keypad is only required for
door access. In this situation, to prevent a user the ability
to turn the area that the keypad has been assigned to on
or o, programming this option will still allow the user to
operate the door strike that have the appropriate access
group level.
Installer PIN Arming Not Allowed
This option prevents the installer PIN to access menus or
to turn the system on or o at any keypad programmed
with this option.
Devices > Keypads > L616
Emergency Keys
MENU 6-1-6
1 Audible Keypad Fire Y
2 Report Keypad Fire Y
3 Audible Keypad Medical Y
4 Report Keypad Medical Y
5 Audible Keypad Panic (Invisible If Not Set) N
6 Report Keypad Panic N
7 Reserved N
8 Reserved N
The above options can be congured independantly for
each keypad tted to the system.
1) Enter your Installer PIN + [MENU].
2) Enter [6] + [1] + [6] + [OK].
The keypad will display the current options which are
selected or enabled.
-bit-
1 2 3 4
3) Use the numeric keys [1] to [8] to turn on and o
the features as required. When the corresponding
number on the keypad is on then the option is
selected.