10-7
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual Device Programming
1) Enter your Installer PIN + [MENU].
2) Enter [6] + [2] + [1] + [OK]. The keypad will display
the current RF supervision time.
d= 024
3) Using the numeric keys, enter the number of hours
for the RF supervision time. Valid times are 0 - 255
hours, 0 = No Supervision.
4) Press [OK] to save and exit or press [MENU] to exit
without saving.
Device > RF Devices > L622
RF Device Options
MENU 6-2-2
1 Display RF Tamper Y
2 Report RF Tamper Y
3 Report RF Low Battery Y
4 Report Lost RF Device Y
5 Open Zone On Lost RF Y
6 Audible Keyfob Panic Y
7 Report Keyfob Panic Y
8 Keyfob Function 1 Key = Part On Y
This menu option allows you to congure various options
and functions for RF devices connected to the system.
1) Enter your Installer PIN + [MENU].
2) Enter [6] + [2] + [2] + [OK].
The keypad will display the current options which are
selected or enabled.
-bit-
1 2 3 4 5 6 7 8
3) Use the numeric keys [1] to [8] to turn on and o
the features as required. When the corresponding
number on the keypad is on then the option is
selected.
4) When all options are programmed, press [OK] to
save and exit, or press [MENU] to exit without
saving.
Display RF Device Tamper
Setting this option will cause the keypad to display the
RF zone when a tamper condition occurs.
Report RF Device Tamper
Setting this option will cause the panel to send an RF
Device Faulted report to the base station when the
devices tamper curcuit is tripped. A restore report will be
sent when the tamper circuit is resealled.
Report RF Device Low Battery
Setting this option will cause the panel to send a report
to the base station when the RF device signals to the
panel that it has a low battery condition.
Report RF Device Missing
Setting this option will cause the panel to send a report
to the base station if the panel detects that an RF device
is missing.
Open Zone On RF Device Missing
Setting this option will cause the panel to show a zone
fault on the keypad for any RF devices that are missing.
Audible RF Key Fob Panic
Setting this option allows users who have RF keyfobs to
trigger an audible panic alarm via the keyfob.
Report RF Keyfob Panic
Setting this option will cause the panel to send a Panic
report to the base station when a panic alarm has been
initiated via a key fob.
RF Keyfob Function Key 1 = Part On’
Setting this option will allow keyfob users to arm an area
or all areas of the system using function key 1 on the