7-5
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual Input Programming
Zone 1
4) Use the [0] to [9], [] and [] keys to change the
Zone Name text as required.
At any time you can use the [] and [] keys to scroll
through the complete list of available characters.
To clear all text from the cursor position to the right,
press the [OFF] key.
5) When the Zone Name is complete, press [OK] to save
and exit, or press [MENU] to exit without saving.
i
Note
See Alpha Text Programming in Section 4 -
Programming Overview for further detail on entering
alpha text.
Inputs > Zone Properties > L311
Zone Type
MENU 3-1-1
0 1
This menu allows you to congure the zone type or
behaviour for every zone in the system. Each zone should
be assigned to a Zone Type that denes the way in which
the panel will respond when an alarm is triggered on that
zone. Refer to the table and descriptions below for the
available Zone Type selections.
00 = Zone Not Used
01 = Burglary Delay 1 (Entry Timer 1)
02 = Burglary Delay 2 (Entry Timer 2)
03 = Burglary Instant 1 (With Exit Delay)
04 = Burglary Instant 2 (No Exit Delay)
05 = Burglary Handover
06 = Burglary 24-Hour
07 = Tamper 24-Hour
08 = Hold Up 24-Hour (Silent & Invisible)
09 = Medical 24-Hour
10 = Panic 24-Hour
11 = Fire 24-Hour
12 = Reserved
13 = Keyswitch Zone
14 = Display Only
15 = 24-Hour Non Burglary
1) Enter yout Installer PIN + [MENU].
2) Enter [3] + [1] + [1] + [OK], then enter the zone
number required, and press [OK].
3) Use the numeric keys and enter the zone type
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
d= 01
0 Zone Not Used
Program the zone type as zero if the zone is not being
used.
1 Burglary Delay 1
Zones programmed as Delay 1 will cause Entry Timer 1 to
start when tripped. The user must disarm the area before
entry timer expires or an alarm will occur. Zones set as
Burglary Delay 1 are only active when the area is armed.
See MENU 7-2-1 — Entry Time 1 to set the required delay
time.
2 Burglary Delay 2
Zones programmed as Delay 2 will cause Entry Timer 2 to
start when tripped. The user must disarm the area before
entry timer expires or an alarm will occur. Zones set as
Burglary Delay 2 are only active when the area is armed.
See MENU 7-2-2 — Entry Time 2 to set the required delay
time.
3 Burglary Instant 1
Zones programmed as Instant 1 will immediatly cause
the alarm to trigger when the zone is tripped. ie No Entry
Delay. Zones set as Burglary Instant 1 have Exit Delay and
are only active when the area is armed. See MENU 7-2-0
— Exit Time
4 Burglary Instant 2
Zones programmed as Instant 2 will immediatly cause
the alarm to trigger when the zone is triggered. ie. No
Entry Delay. Zones set as Burglary Instant 2 have NO Exit
Delay and are only active when the area is armed.
5 Burglary Handover
A Handover zone will provide a delayed alarm only when
a delay zone has been tripped rst (ie. the entry time is
active) otherwise it will trigger an instant alarm.
Zones programmed as Handover can be set to sequential
or non-sequential handover. At factory default, handover
is set to sequential which means that zone must be
triggerred in numerical order for the delay to handover.
Non Sequential Handover means the zone do not have
to be programmed in numerical order. In both cases an
entry delay zone must be triggered rst for the delay to
handover.
See MENU 2-1-2 — Input Options to set Non Sequential
Handover.
i
Note
The Zone Types listed above will only trigger an
alarm if the system or area is in the armed state and
the exit time has exprired. Zones must be sealled at
the end of exit time to trigger alarms.