EasyManua.ls Logo

Bosch Tronic 1000 T - Page 50

Bosch Tronic 1000 T
56 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
50 | Regulator
Tronic 1000 T6 720 801 512 (2013/10)
3 Regulator
The country’s regulations currently in force must be fulfilled for the
installation of the electric appliances
4 Installation (only for authorized installers)
4.1 Important information
4.2 Selecting the installation location
Dispositions relative to the place of installation
Comply with country-specific requirements
Never install the appliance above a heat source.
Never install the appliance in rooms where the ambient temperature
can fall below 0 °C.
Install the appliance near the most frequently used draw-off point to
keep energy losses and waiting times to a minimum.
Install the appliance in a room that permits the replacement of the
magnesium anode, and necessary maintenance procedures.
Protection areas 1 and2
Do not install in protection areas 1 and 2.
Install the appliance outside the protection areas at a distance greater
than 60 cm, of the bath.
Fig. 5 Protection areas
4.3 Water connection
It is recommended to purge the system before appliance installation, the
existence of sand can cause a reduction in flow or even cause a total
obstruction.
Identify the piping for hot and cold water, in order to avoid a possible
swop (FIg. 6).
Fig. 6
[1] Cold water inlet (right hand side)
[2] Hot water outlet (left hand side)
The installation, the connection to the electric power, for
the initialization of the process must be exclusively be
done by an authorized technician.
CAUTION:
Do not drop the appliance.
Remove the appliance from the packaging only at the
place of installation.
Wherever applicable, comply with the IEC 60364-7-
701 norm on installing the appliance and / or any
electric accessories.
Chose a sufficiently robust wall to support the
appliance with the tank full, see page 4.
CAUTION: Damage to the heating elements!
Firstly connect all the water connections and fill the
appliance.
Connect the appliance to the electric point, assuring
connection to earth.
CAUTION:
Make sure that the appliance is connected to the DB
board (electrical board) with a connection to the earth
cable.
CAUTION: Corrosion damage on the connection cables
to the appliance!
Use galvanized insulators in your water connections.
These will avoid galvanic electric currents between
the hydraulic link metals and , consequently corrosion
of these.
NOTICE: Material damage!
Install a filter at the water inlet in areas where the
water contains particles or sediments.
DANGER:
Install a safety valve at the water inlet of the appliance
( Fig. 7).