EasyManua.ls Logo

Bosch Tronic 1000T - Seismic Strapping; Seismic Restraint Requirements

Bosch Tronic 1000T
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 720 821 421 (2017/04)Tronic 1000 T
Seismic strapping | 15
7 Seismic strapping
New Zealand regulations require storage tanks to be fixed with
seismic strapping as per NZS4603 or NZS4607.
Fig. 6
[A] Extra centre strap for water heaters exceeding 200L
[B] Storage water heaters to be restrained with 25x1
galvanized steel straps tensioned when fixed in place.
Straps to be fixed to wall framing with:
- 1 No. 8 coach screw with 30x2 thick washer, or
-2 No. 20x2.5 thick washers.
Screws to penetrate timber framing a minimum of 50.
[C] 50x50 vertical blocking full height of water heater, fixed
to wall framing with 1 No. 100x3.75 nail at 600
maximum centres
[1] Storage water heating
[2] Light timber frame wall