Troubleshooting
15
Tronic 3000T – 6 720 801 072 (2022/07)
Table 4
7.1 Resetting High Limit Switch
Occasionally, the high temperature limit shut off device may
trip the reset. This occurs when water temperature exceeds
190 °F. The shut off device may also trigger from a power
outage or electrical storm.
To reach the thermostat:
Disconnect power cord (or shut off circuit breaker - model
ES8) and remove the front cover.
Firmly press reset button [B] with the tip of a ball point pen
or similar object.
Fig. 13
A click indicates the reset was tripped.
Reconnect power.
IMPORTANT: Check the operation of the thermostat:
Turn temperature dial from high to low.
If the red light does not go off on low setting:
Turn off power supply and call a service person to replace
the thermostat.
If the red light does go off the thermostat is working well:
Place dial setting to desired setting.
A lower setting is more economical, reduces the risk of
scalding, and may also help to slow down the natural
accumulation of lime scale inside the water heater.
Replace cover plate.
CAUTION:
Call a technician if the high limit needs to be reset frequently.
Frequent activation of the high limit may indicate that lime scale
has formed on the heating element.
Please refer to section 5.5 Descaling the Heating Element
for further details.
7.2 Online Resources
For more technical tips, service bulletins, videos, and FAQs,
please visit our Support webpage here;
www.boschheatingcooling.com/techsupport.
Alternatively, you can scan the code below with your cellphone!
Fig. 14 QR code
6720801072-12.1V