18 | Maintenance
Using an ohm meter to check for premature element failure
Fig. 13 Heating elements
On WH17 model, there is no middle element
Meter probes Ohm Readings
Outer to Outer 10.5 ± 0.6 Ohms
Middle to Middle 11.7 ± 0.8 Ohms
Inner to Inner 15.1 ± 1 Ohms
Table 9
Meter probes Ohm Readings
Outer to Outer 10.5 ± 0.6 Ohms
Middle to Middle 11.7 ± 0.8 Ohms
Inner to Inner 21.0 ± 1.2 Ohms
Table 10