Control unit
Uni Condens 8000 F – 6720867056 (2016/10)
26
7.2.1 Fitting the control unit
fig. 24, page 26 shows the control unit and the front cover hood [1] from
the back.
Undo both screws in the cover hood [1].
Lift off the cover hood.
Fit the control unit at the front by inserting the locking tabs [4] into
the oval holes in the front boiler cover [5].
Pull the control unit forwards and then tip backwards. The resilient
hooks [2] must latch into the rectangular openings at the back of the
front boiler cover [3].
Screw the base of the control unit to the control unit holder with 2
sheet-metal screws.
Fig. 24 Fitting the control unit
[1] Cover hood
[2] Flexible hooks
[3] Openings in the front boiler cover/control unit holder
[4] Locking tabs
[5] Oval holes in front boiler cover
[6] Cable feed in the front boiler cover
[7] Holes for self-tapping screws
Fig. 25 Fitting the control unit
7.2.2 Electrical connection of the control unit
If necessary, make knock-outs [1] in the rear panel of the cable duct
or remove the rear panel section [2].
Fig. 26 Preparing the cable entry
[1] Knock-outs
[2] Back panel section
Route the sensor lead separately from other cables.
Make the plug-in connection in the control unit in accordance with the
labelling on the terminal strip.
Route the burner cable through the cable feed in the front boiler
cover to the control unit.
Connect the burner cable to the control unit in accordance with the
labelling on the plug-in strip.
Make all electrical connections to the appropriate plug-in connectors
according to the wiring diagram.
001001535-001