Regulations
2.6 Product information
3 Regulations
Observe the following guidelines and standards:
Local regulations
EnEG (Building Regulations) (in Germany)
EnEV (Energy Savings Order) (in Germany)
Installation of, and equipment for, heating and water heating systems:
DIN and EN standards
DIN 4753-1 – Water heaters ...; requirements, identification,
equipment and testing
DIN 4753-3 – Water heaters ...; corrosion protection on the
water side through glass lining; requirements and testing
(product standard)
DIN 4753-6 – Water heating systems ...; cathodic corrosion
protection for enamelled steel cylinders; requirements and
testing (product standard)
DIN 4753-7 – Water heaters...; containers with a volume up to
1000 l, manufacturing, thermal insulation and corrosion
protection requirements
DIN EN 12897 – Water supply - regulation for ... DHW cylinders
(product standard)
DIN 1988-100 – Technical rules for potable water installations
DIN EN 1717 – Protection of potable water against
contamination ...
DIN EN 806 – : Technical rules for potable water installations
DIN 4708 – Central water heating systems
DVGW
Code of Practice W 551 – Potable water heating systems
and pipework; technical measures to inhibit the growth of
legionella bacteria in new systems; ...
Code of Practice W 553 – Sizing DHW circulation systems ... .
4 Transport
Secure the DHW cylinder during transportation to prevent it from
falling.
Move packed DHW cylinder with a sack trolley and lashing strap
( Fig. 4, page 45).
-or-
Move unpacked DHW cylinder with a transport net; during handling,
protect connections against possible damage.
5 Assembly
The DHW cylinder is delivered fully assembled.
Check that the DHW cylinder is complete and undamaged.
5.1 Installation
5.1.1 Requirements for installation location
Place the DHW cylinder on a plinth if there is a risk of water collecting
at the installation location.
The installation site must be a dry and frost-free room.
Observe minimum room height ( Tab. 10, page 44) at the
installation location. No minimum wall clearance required.
5.1.2 Positioning the DHW cylinder
Stand the DHW cylinder upright and level it ( Fig. 6, page 46 and
Fig. 7, page 46).
Remove the caps.
Apply Teflon tape or Teflon string ( Fig. 8, page 46).
5.2 Hydraulic connections
Item Description
1 Casing, painted sheet metal with rigid polyurethane foam
thermal insulation, 30 mm
2 Built-in magnesium anode, without electrical insulation
3 Heat exchanger for reheating by wall mounted boiler,
smooth enamelled tubing
4 Sensor pocket for temperature sensor, heat source
5 Storage cylinder, enamelled steel
6 Inspection aperture for maintenance and cleaning on the
top/DHW circulation connection
7 PS top cover
8 Cylinder flow
9 DHW outlet
10 Cold water inlet
11 Cylinder return
12 Drain valve
Table 6 Product description ( Fig. 3, page 45)
NOTICE: Risk of damage from inadequate load-bearing
capacity of the installation surface or unsuitable floor
surface!
Ensure that the installation surface is level and offers
sufficient load-bearing capacity.
WARNING: Risk of fire from soldering and welding!
Take appropriate safety measures when soldering
and welding as the thermal insulation is flammable.
For example, cover up the thermal insulation.
Check cylinder jacket for damage after completing
work.
WARNING: Risk of injury from contaminated water!
Work carried out without due care for cleanliness
contaminates the potable water.
Install and equip the DHW cylinder hygienically in
accordance with national standards and guidelines.