Operation 21/46
RE51550-B/09.2019, BoschRexrothAG
5.1.6.5 Defining the switching outputs
Here you can define the switching outputs.
Using the function "Define switching outputs", you can define the switching outputs
(
R.OUi
and
R.OU2
). It is possible to define the switching outputs as
eRR
,
hUMi
or
TeMp
.
The following options are available:
Err TEMP HuMi
Notice:
The switching outputs 1 and 2 can alternatively be connected as
error indicators. In this case, the output is connected as a normally
closed contact which opens when the range is exceeded or another
error state. However, the LED assigned to the output is generally not
activated, as all 6 LEDs in the status bar flash when an error occurs.
If a switching output is defined as an error indicator, it is no longer
available in the normal switching output settings.
5.1.6.6 Setting the update rate of the display
The update rate of the display can be set depending on the application.
The display can also be switched off completely. The function of the LED remains
unchanged.
The following options are available:
quick medium slow display off
Notice:
Error messages are displayed even if the display is switched off.