2727
930mm
410mm
+30mm
above elbow
5mm
5mm
200mm
20mm to
removable
door
600mm front
clearance
for service
Using 100mm
flue kit
– 1,080mm
Using 125mm
flue kit
– 1,110mm
Clearances for Greenstar i Junior
+30mm
above elbow
200mm
200mm*
200mm
100mm to
removable door
600mm front
clearance for
service
Greenstar i Junior
*This can be reduced to 50mm for one side, provided that the total side
clearances add up to 400mm or more.
Ventilation-free compartment installation – minimum clearances
Boiler location
The appliance may be installed in any room, although
particular attention is drawn to the requirements of the
IEE regulations applicable, and in Scotland the electrical
provisions with respect to installation in a room containing
a bath or shower.
1. The room in which the appliance is installed does not
require a purpose-provided air vent.
2. If the appliance is installed in a cupboard or
compartment with dimensions that allow the following
minimum clearances, then no ventilation is required:
Compartment installation
Position of
appliance
Minimum unventilated clearance
(to removable door)
Greenstar
CDi Classic
Greenstar
CDi Compact
& Si Compact
Greenstar
i Junior
In front 20mm 20mm 100mm
Below 200mm 200mm 200mm
Right side 5mm 5mm 200mm*
Left side 5mm 5mm 200mm*
Above
fl ue elbow
30mm 30mm 30mm
*This can be reduced to 50mm for one side, provided that the total side
clearances add up to 400mm or more.