6.
\
'
'
REPLACEMENT
OF
PARTS
REPLACEMENT
OF
PARTS
6.
Gas valve
~
Isolate gas
supply
at boiler gas cock.
~
Pull
out
air inlet
tube
(A).
6.1
~
Undo
top
gas
connection (B)
to
gas valve.
6.1
~
Undo
bottom
gas
connection
(C)
to
gas
valve.
6.2~
Undo
two
securing
screws
(D) on the
underside
of
casing.
~
Pull valve
up
and forward
out
of
boiler.
~
Disconnect
electrical connections.
~
Replace valve with
new
seals and
check
for gas soundness.
Note:
The
valve
will
require setting, follow
pro-
cedure "Setting the gas/air ratio"
in
the gas
conversion section.
7.
Siphon
7.1
~
Pull
condensate
pipe
out
of
the adapter.
7.2
~
Remove trap from boiler.
~
Clean trap and
check
that the connection
to
the heat exchanger is clear.
~
Fill
the
condensate
trap with approxi-
mately
1/4
litre
of
water
and refit
in
reverse
order.