~ORCESTER
INSTALLATION
&
SERVICING
INSTRUCTIONS
FOR
WORCESTER
BOSCH
GREENSTAR
25CDV30CDV37CDc!42CD'
Bosch
Group
6
720
613
700a
(2006/11)
REPLACEMENT
OF
PARTS
14.
Air/gas
manifold
14.1
~
Remove cover panel (A) by removing
the
screws
(B).
~
Check
that the boiler is completely iso·
lated
from the
gas
supply.
14.2
~
Remove the clips (C) and unscrew the
two
bolts (D).
~
Unscrew and remove the
two
hexagon
screws
(E) securing the fan.
~
Slacken fully the rear securing bolt
(F).
14.3
~
Remove air/gas manifold
(I)
14.4
~
Open
air/gas manifold
(1).
~
Carefully
withdraw
diaphragm
(J)
from
fan intake tube and
check
for
soiling and
splits.
15.
Burner
~
Remove the burner (H).
~
Replace
new
burner
in
correct
posi·
lion.
~
Ensure that a new seal (K) is used.