Appliance information
Greenstar Danesmoor External
ErP+
and External System
ErP+
6720821725 (2018/04)6
3 Appliance information
3.1 General information
Standard package:
A - Floor standing oil fired condensing boiler
B - Literature pack:
Greenstar Danesmoor external Installation, Commissioning and
Servicing instruction manual
User Instructions
Guarantee registration card
C - Condensate trap
D - BSP plug, one inch (Regular only)
E - ErP label
F - Flue damper
G - Balanced flue kit
H - 100mm Ø Services duct
J - Cabinet key
Fig. 1 Standard package
3.2 Technical data
6720821725-03.1Wo
A
B
C
DE
H
J
G
F
Description Units 12/18 18/25 25/32
Central heating
Central heat output (max) kW 18 25 32
Primary water capacity (total) litres 20 21 22
Max.static head (Regular only) metres 30 30 30
Min. static head (Regular only) metres 111
Water side resistance (20°C
difference)
mbar 20 30 56
Maximum available pump head
(20°C difference) System only
mH
2
O 5.2 4.3 4.1
Maximum permissible sealed
system operating pressure in
accordance with WRAS
guidelines
bar 2.5 2.5 2.5
Flue
Exit flue gas mass flow kg/hr 29 40 51
Pipework connections
Fuel line (compression) mm 10 10 10
Flow Kitchen BSP 1” 1” 1”
Flow Kitchen System mm 22 22 28
Kitchen flow and optional vent/
air vent
BSP 1” 1” 1”
Return mm 22 22 28
Condensate (Polypropylene) mm 21.5 21.5 21.5
PRV outlet - System only mm 15 15 15
Electrical
Electrical power supply voltage ac ..V 230 230 230
Frequency Hz 50 50 50
Thermostats
Boiler flow temperature range
(cut in/cut out)
°C 55/81 55/81 55/81
Control thermostat differential °C 555
Boiler high limit thermostat set
point
°C 95 95 95
Boiler manual reset overheat
thermostat set point
°C 105 105 105
Flue manual reset overheat
thermostat set point
°C 110 110 110
General data
Maximum hearth temperature °C <100 <100 <100
SEDBUK 2009 % 91.1 90.9 90.7
SEDBUK 2005 % 93.2 93.0 92.8
Appliance protection rating IP 45 45 45
Weight (excluding packaging)
External Regular
kg 110 114 124
Weight (excluding packaging)
External System
kg 119 121 131