PRE-INSTALLATION
6 720 821 670 (2018/06)24
High level horizontal flue
High level horizontal flue with additional elbows
High level horizontal flue with additional elbows
Vertical balanced flue assembly
Vertical balanced flue with elbow offset (2 x 90 ° bends)
Vertical balanced flue with elbow offset (2 x 45 ° bends)
Maximum flue length
(mm)
60/100 80/125
High level horizontal flue 4,600 13,000
Table 24
Maximum flue length
(mm)
60/100 80/125
High level horizontal flue with 2 x 90° bends 2,600 11,000
Table 25
Maximum flue length
(mm)
60/100 80/125
High level horizontal flue with 3 x 90° bends N/A 9,000
Table 26
6720806945-22.1Wo
6720806945-24.1Wo
Maximum flue length
(mm)
60/100 80/125
Vertical balanced flue assembly 6,400 15,000
Table 27
Maximum flue length
(mm)
60/100 80/125
Vertical balanced flue with 2 x 90° bends 2,400 11,000
Table 28
Maximum flue length
(mm)
60/100 80/125
Vertical balanced flue with 2 x 45° bends 4,400 13,000
Table 29
6720806945-25.1Wo
A = 300 mm
B = 500 mm
6720806945-26.1Wo
6720806945-27.1Wo