Page 21 from 43 6 720 887 547 “SM FP_ErP MPP Europe 2018/08 en”
Pict.27 Ionization electrode and its sealing element
Pict.28 Ignition electrodes position on the burner
5. Working Principle / Electric Measurements
Water Flow Detection and solar mode operation
Water Flow Calculation
procedure
WF = Power
(T
set
T
in
)
WF ≥ 2.8 l/min
Burner ON
WF < 2.4 l/min
Burner OFF
Burner On
Solar mode Operation
Burner Off
T
in
T
set
1K
T
out
< 60ºC
(if T
set
≤ 50ºC)
or
T
out
< T
set
+
10ºC
(if T
set
> 50ºC)