Fault diagnosis
2013-10-23 / DIS 113_58300000133444_ara_en_l Repair Instructions Laundry Repair Instruction;T22 Page 13 of 35
4.1 Malfunctions
Fault Possible cause Troubleshooting
Washing too dry (drum empty detection)
Underload
► Also select timer programme
Error in the conductivity system
Humidity sensors have become coated
► For cleaning see operating instructions
Drying programme starts only briefly
Door lock function (open briefly) ► Advise customer
Switching contact does not switch ► Replace door switch
Cable break ► Replace cable
Motor not rotating ► Run motor test programme.
► Check motor capacitor / Replace
► Replacing the motor
Belt torn ► Replace belt.
Driving system
Drum does not turn
Rolling rollers damaged ► Replace rolling rollers of bearing shield.
Heat pump driers do not become very
warm
► Not a faultHeating system
Appliance remains cold
Heat pump defective ► Run heat pump test programme (See circuit diagrams)