Installation | 43
6 720 643 068 (2011/06)Copyright (optional information)
5.8 Connecting flue gas accessories
B Install the vent flange and gasket with the screws
enclosed.
Fig. 22 Attaching the vent flange and gasket
1 Gasket
2 Vent flange
3 Screws
B Insert the flue gas adapter as far as it will go into the
vent flange and align it.
Fig. 23 Flue gas adapter
1 Vent flange
2 Flue gas adapter
3 Combustion air test port
4 Flue gas test ports
B Tighten the screws.
B Insert the venting accessory as far as it will go into the
vent flange.
Fig. 24 Vent pipes
In case of open venting use basket on the air intake.
For more details on connecting the flue
system, refer to the installation instructions
for the flue kit.
1
2
3
6 720 612 737-01.1O
To avoid premature wear of the gaskets DO
NOT use lubricants.
6 720 641 933-85.1O
3
4
1
2
6 720 641 933-26.1O

Table of Contents