4.3 Starting the central heating
The maximum flow temperature can be matched to the heating
system by the flow temperature controller. The current flow
temperature is shown on the display.
Setting on flow
temperature
controller
Flow
temperature
Sample
application
1 Approx. 35 °C
2 Approx. 43 °C
3 Approx. 50 °C Underfloor
heating system
4 Approx. 60 °C
5 Approx. 67 °C
6
Approx. 75 °C
Radiator heating
system
max. Approx. 90 °C Convector
heating system
Table 3
With underfloor heating systems, take care to
observe the maximum permissible CH flow
temperatures.