EasyManua.ls Logo

Bosch ZWB24-1AR Series - C7 Fan Sensor Not Detected

Bosch ZWB24-1AR Series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14 | Failures / Errors
C7 and operating LED is flashing.
Fan sensor not detected.
( This failure only occurs if there is a sensor or the cable physical defect)
Control Step Action
1. Is th fan cables damaged ? yes: B Switch off the appliance.
B Change the cables.
B Switch on the appliance.
C7 failure still exist ? -->2.
no: -->2.
2. Is there any problem at fan sensor and
cable ?
B Switch off the appliance.
B Check the sensor and cable.
yes: B Change the cable and sensor.
B Switch on the appliance.
C7 failure still exist ? -->3.
no: -->3.
3. Electronic card is defect. B Switch off the appliance.
B Cut mains supply.
B Change the electronic card.
B Connect to main supply.
B Switch on the appliance.

Related product manuals