Gas type conversion | 75
6 720 643 068 (2011/06)Copyright (optional information)
11 Gas type conversion
The gas-air ratio must always be set on the basis of a CO
2
or O
2
reading taken at maximum nominal output and
minimum nominal output using an electronic flue gas
analyzer.
Adjustment to different flue systems using throttle discs or
baffles is not necessary.
NG
Appliances are set at the factory to Wobbe index
1,333 BTU/ft
3
(49.6 MJ/m
3
) at 60 °F (15 °C), 30" Hg
(1016 hPa)
and 7.0" W.C. (17.4 mbar) gas supply
pressure and sealed.
11.1 Converting to a different gas type
A gas conversion kit is included in the scope of delivery.
B Fold the Heatronic down.
B Check the number on the code plug from the gas
conversion kit (Code plug number Æ table 42, page 96).
B Replace the code plug in the Heatronic with the code
plug from the gas conversion kit.
Fig. 67 Replacing the code plug
B Affix the gas type label from the gas conversion kit to
the appliance.
Fig. 68 Affixing the gas type label
B Always adjust the gas-air ratio (CO
2
or O
2
,
Æ Section 11.3) after converting to a different gas type
and measure the CO content of the flue gas
(Æ Section 12).
DANGER: Personal injury and property
damage
B This conversion shall only be performed by
a trained and certified installer in
accordance with the manufacturer‘s
instructions and all applicable codes and
requirements of the authority having
jurisdiction.
B If the information in these instructions is
not followed exactly, or the installation,
adjustment, modification, operation or
maintenance is carried out by an
unqualified person, a fire, explosion or
generation of large amounts of carbon
monoxide may result causing property
damage, personal injury or loss of life.
B Before carrying out electrical work:
Disconnect the installation from the power
supply at the emergency shutoff switch or
by disengaging the heating system circuit
breaker. Take measures to prevent
accidental reconnection.
B The installer is responsible for the proper
conversion of this appliance.
B The conversion is not complete until the
operation of the converted appliance is
checked as specified in these instructions.
DANGER: Explosion!
B Close the gas cock prior to working on the
gas train.
B Check for gas leaks after carrying out work
on the gas train.
6 720 641 933-57.1O