5704 - 9
BINC Rev: 11/97 Service Documentation
Service Information
BAG Rev: 8/97 5704
Attention! Do not check the function of the long hair trimmer after inser-
ting the sliding plate otherwise the transmission lever will
unhinge and the sliding plate will have to be attached again!
Display (27) - to be inserted in the chassis with the contact strips (28)
pointing towards the lower end. Ensure that the contact
strips are free of grease and dirt.
Motor (17) - Apply a small amount or Vaseline to the motor axis and
eccenter pin.
- Snap into holder with the spring's wide side pointing
downwards.
Cover (19) - to be hanged into the chassis (10) exactly with the notches “B”.
Housing case (30) - The latch (15) in the chassis and the locking button (31)
have to be in position "unlock".
Swivel frame (4) - to be inserted in head carrier (8) with the unlocking pin
towards button "A".
- Motor eccenter to be inserted in oscillating bridge lead.
Bearing screws (6) to be tightened carefully.
All functions to be tested.
Electronics-Reset and Test (Don't open appliance).
The electronics test can only be started out of the Reset mode.
Procedure:
Device to be discharged out of standard operation, until "0" is displayed.
Connect to mains power for approx. 20 sec., but less than 2 min. Display is empty, only
green LED is illuminated.
Device to be totally discharged (approx. 10 min.; Display "0"). Keep the unit switched on
for further 15 min., then switch off.
Connect to mains power.
Switch on device. Reset-and control functions are displayed (see dia.). Now, the device has
to be switched off.