EasyManua.ls Logo

BRIGHT BLUE SANUS User Manual

BRIGHT BLUE SANUS
45 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
!
!
!
!
!
!
!
!
!
!
!
!
!
!
"#$%&#'!!
()%*+),$-)+!-.!/0!1!/0!()%*+),.+!!
.234567! ! 89!
/6:;<=<>2! ! !!?!
.@=7A2B!! ! CD!

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the BRIGHT BLUE SANUS and is the answer not in the manual?

BRIGHT BLUE SANUS Specifications

General IconGeneral
BrandBRIGHT BLUE
ModelSANUS
CategoryController
LanguageEnglish

Summary

Welcome

Safety Instructions

Safety Warnings

Highlights critical risks including electrocution, chemical handling, and human error.

EC Conformity

Package Contents

Operation

Front Panel Overview

Describes the front panel layout, including the screen and the round command button functions.

Installation

Hydraulic Installation

Details the steps for the hydraulic installation of the SANUS pH controller.

Electrical Installation

Covers the electrical installation requirements and provided cables for the equipment.

First Operation

Menus

Introduction to Menus

Explains the circular menu navigation by rotary actuator and button press.

Main Menu

Displays system status, set-value, and current pH, with indications for active alarms.

Menu On/Off

Details the function of switching the equipment on/off and its effect on readings and compensation.

Setup Menu

Describes accessing the configuration menu, including password entry.

Setup Configuration

Setpoint Setup

Allows adjustment of the pH setpoint, with a default value of 7.1.

Limits Setup

Adjusts the pH interval outside which compensation is activated.

Alarm Setup

Adjusts the pH interval outside which alarms are triggered.

Timeout Alarm Setup

Adjusts the time to deactivate compensation after a Timeout Alarm.

Type of Compensation Solution

Defines the type of compensation solution used (acid or base).

Dosing Pump Priming

Explains the procedure for priming the pH dosing pump.

Password Management

Change Password

Allows changing or disabling the predefined password for menu access.

Calibration Menu

Importance of Calibrating

Explains why sensor calibration is crucial for system accuracy and prompt response.

When to Calibrate

Recommends calibration checks upon installation and periodically, or when readings are anomalous.

Who Should Perform Calibration

States that calibration should only be performed by technically skilled personnel.

How to Calibrate

Prepares the user for calibration by ensuring necessary tools and materials are ready.

pH Calibration Using Buffers

Details the process of calibrating the pH sensor using buffer solutions.

Adjustment by DPD

Explains how to calibrate using a DPD photometer if buffer solutions are unavailable.

Alarms Menu

Alarms Menu Overview

Describes the system's alarms, including pH Fault, Empty Tank, and pH Timeout.

pH Fault Alarm

Details the pH Fault alarm, its causes, and troubleshooting steps.

Empty Tank Alarm

Explains the Empty Tank alarm and actions for refilling or checking the buoy.

pH Timeout Alarm

Describes the pH Timeout alarm, indicating issues with pH correction or sensor reading.

Terms and Conditions

Copyright Information

States that the User Manual content is secured by copyright and reserved to Bright Blue, Lda.

User Responsibilities

Details user responsibilities for reading, understanding, and following the manual for safe operation.

Product Warranty

Covers the warranty period for the equipment, dosing pump, and probes.

Warranty Exclusions