errDump and errShow
Use the errShow command to display device error log messages one at a time. Use the errDump command to display
error log messages without any page breaks. The output of these commands are unique for each Control Processor (CP),
so must be executed on each CP blade to obtain a complete record.
The following partial example shows the output of the errDump command.
chassisX7:admin> errdump
2016/03/28-08:44:28,[FV-1001], 90, SLOT 1 CHASSIS,INFO,My_Switch,Flow Vision daemon initialized.
2016/03/28-08:44:51,[FSSM-1002],91,SLOT 1 CHASSIS,INFO,My_Chassis,HA State is in sync.
2016/03/28-08:44:51,[SULB-1003],92,SLOT 1 CHASSIS,INFO,My_Chassis,Firmwarecommit has started.
2016/03/28-08:48:27,[SULB-1004],93,SLOT 1 CHASSIS,INFO,My_Chassis,Firmwarecommit has completed.
2016/03/28-08:48:27,[SULB-1036],94,SLOT 1 CHASSIS,INFO,My_Chassis,The new Version: Fabric OS v8.0.1_bld52.
2016/03/28-08:48:27,[SULB-1002],95,SLOT 1 CHASSIS,INFO,My_Chassis,Firmwaredownload command has completed
successfully.
2016/03/28-08:50:51,[IPAD-1003],96,SLOT 1 CHASSIS,INFO,My_Chassis,DNS parameters saved successfully.
------------------------------------------------------------------------------------------------------------
Note the following about this output:
•
The output can contain several thousand lines. Use the errClear command to reset the output when needed. This
command clears all error log messages for all director instances on the CP where the command is issued.
•
My_Switch corresponds to what is entered for switchname and is a switch or logical switch event.
•
My_Chassis corresponds to what is entered for chassisname and is a chassis event.
fanShow
Use the fanShow command to display the current status and speed of each installed fan. The following example displays
output from this command.
chassisX7-4:admin> fanshow
Fan 1 is Ok, speed is 6993 RPM