IV-58
2.4 Power Supply Unit
(1) Outputs and Use
Output Terminal Rated Output Use
+5V-1 For control of the printer
+5V-1R
4.8 ∼ 5.3V, 7.5A
For control of the laser
+5V-2 For control of the interface
+24V-1 +24V, 4.5A For control of printer charging.
HP
HN
120V, 8A (For USA)
220V, 5A (For Europe)
For connection of the fuser heater (HP).
For connection of the fuser heater (HN).
(2) Layout of Connector Pin Assignment
See Fig.4-40 on the following page.