EasyManua.ls Logo

Brother HL-2400C - 4.1.13 Main Gear Unit; Transfer Solenoid (TRSOL)

Brother HL-2400C
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VII-14
4.1.13Main Gear Unit
1) Remove the screws ST3X6 (3 pcs.) and loosen the screw BT4X8 (1 pc.) holding the
rear plastic cover plate and then remove the stay (R).
2) Remove the upper set screw ST3X6 (1 pc.) from the ozone fan case.
3) Remove the ozone fan duct.
4) Remove the set screws ST3X6 (5 pcs.) from the main gear unit.
5) Remove the top cover securing screw to release the top of the gear unit plate.
6) Remove the main gear unit from the frame.
Fig.7-18
Note:
The black plastic cap covers the thread of the screw marked
.
Be sure not to lose the
cap when removing the screw.
4.1.14Transfer Solenoid (TRSOL)
1) Remove the set screws ST3X6 (2 pcs.) from the transfer solenoid.
2) Open the rear access cover.
3) Remove the transfer solenoid.
Fig.7-19
Note:
The black plastic cap covers the thread of the screw marked
.
Be sure not to lose the
cap when removing the screw.
Transfer Solenoid
Stay (R)
Ozone fan duct
Main Gear Unit
Plastic cover plate
Rear Access Cover

Table of Contents

Related product manuals