VII-29
4.3.4 Drum Encoder Sensor (EN)
1) Remove the sensor case assembly from the frame (L).
2) Disconnect the connector (1 pc.) to the encoder sensor.
3) Remove the encoder sensor from the sensor holder.
Fig.7-46
4.3.5 Fuser Connector
1) Remove the PN/PH connectors connected to the DC power supply unit.
2) Remove the shoulder screws SP3* (2 pcs.) from the fuser connector.
3) Remove the fuser connector.
* The set screw of the fuser connector is unique.
Fig.7-47
Fuser Connector
Drum Encoder
Sensor