VII-36
4.4.3 Cleaning Roller Sensor (CRS)
1) Disconnect the harnesses connected to the cleaning roller sensor.
2) Remove the cleaning roller sensor from the paper exit guide (paper exit stay).
Fig.7-60
4.4.4 Discharger Brush
1) Remove the set screws BT4X6 (2 pcs.) from the discharger brush.
2) Remove the discharger brush and the plastic retainer.
PRECAUTION
Do not deform the fur brush of the discharger brush.
Fig.7-61
Cleaning Roller Sensor
Dischar
er Brush
Plastic retainer
Paper exit
uide
Paper exit
uide