8.15 Transfer HVPS PCB Unit
(1) Disconnect the four Connectors from the Electrode head.
Fig. 3-41
(2) Disconnect the flat cable (CN1) and two connectors (CN5, CN8) from the Registration relay
PCB unit.
CN8
CN5
CN1
Fig. 3-42
Connector
Transfer HVPS PCB unit
Electrode head
Registration relay PCB ASSY
Transfer HVPS PCB unit
<Back side>
<Back side>