EasyManua.ls Logo

Brother HL-4040CN - Operational Check of Fans (Function Code 78)

Brother HL-4040CN
333 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Confidential
5-20
1.4.16 Operational Check of Fans (Function code 78)
<Function>
This function is to check whether each of fans is operating correctly or not. The following fans
are checked.
LCD Parts Name Description
FU Fuser unit fan Evacuate hot air of the fuser unit.
OPC Drum unit fan Evacuate hot air of the drum unit drive motor.
PS LVPS fan Evacuate hot air of the LVPS unit.
AIR Air intake fan Intake air to prevent a dirt on the corona wire.
<Operating Procedure>
(1) Press the or button to display “MAINTENANCE 78” on the LCD in the initial stage of
the maintenance mode. Then, press the OK button.
(2) Press the Go button to check the next term. For operation check, spin or stop fans actually
on each term.
Fig. 5-9
(3) Press Cancel button in any process of the display cycle. The machine returns to the initial
stage of the maintenance mode.
Note:
If the air intake fan (AIR) error occurs, the following error message appears on the LCD.
If you press the Cancel button, the machine returns to the initial stage of the maintenance
mode without recovering from this error. To recover from this error, turn the power switch of the
machine off and then turn it on again.
Fig. 5-10