2-77
Confidential
Error code DE
When the center thermistor is higher than the idle temperature, it is detected that the side
thermistor temperature is lower than 60 °C.
Error code E0
Program error. (An error occurred in the ROM checksum.)
Error code E1
Program error.
Print Unable DE
Turn the power off and then back on again.
Step Cause Remedy
1 Harness connection failure
between paper eject sensor PCB
ASSY and fuser unit
Check the harness connection between
the paper eject sensor PCB ASSY and
fuser unit, and reconnect it.
2 Side thermistor or center
thermistor failure
Replace the fuser unit.
3 Paper eject sensor PCB ASSY
failure
Replace the paper eject sensor PCB
ASSY.
4 Main PCB failure Replace the main PCB ASSY.
Print Unable E0
Turn the power off and then back on again.
Step Cause Remedy
1 Firmware update failure Upload the latest firmware.
2 Main PCB failure Replace the main PCB ASSY.
Print Unable E1
Turn the power off and then back on again.
Step Cause Remedy
1 Firmware update failure Upload the latest firmware.
2 Main PCB failure Replace the main PCB ASSY.